2. LIFT OPERATIONAL TROUBLESHOOTING
For the lift operational troubleshooting guide, refer to Table [4-3]:
TABLE [4-3]: OPERATIONAL TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE REMEDY
ROLLSTOP DOES NOT OPEN Obstruction of rollstop
release latch.
Raise lift and remove
obstruction.
NO LIFT OPERATION Control System Circuit
Breaker tripped.
Reset circuit breaker.
Main Circuit Breaker
tripped.
Reset circuit breaker.
IN OR OUT FUNCTIONS Abnormal
Operation.
Obstruction in lift
carriage.
Remove obstruction and
check for any damage
No Operation. Control System Circuit
Breaker tripped.
Reset circuit breaker.
Main Motor Circuit
Breaker tripped.
Reset circuit breaker.
UP OR DOWN
FUNCTIONS
Abnormal
Operation.
Obstruction in lifting
frame.
Remove obstruction and
check for any damage
Backup pump manual
release valve OPEN.
Turn manual release
valve CLOCKWISE until
lightly-snug.
No Operation. Control System Circuit
Breaker tripped.
Reset circuit breaker.
Backup pump manual
release valve OPEN.
Turn manual release
valve CLOCKWISE until
lightly-snug.
Hydraulic hose or fitting
leak.
Contact an authorized
Ricon dealer for repair.
MANUAL FUNCTIONS Abnormal
Operation.
Obstruction in lifting
frame.
Remove obstruction and
check for any damage
Backup pump manual
release valve OPEN.
Turn manual release
valve CLOCKWISE until
lightly-snug.
No Operation. Backup pump manual
release valve OPEN.
Turn manual release
valve CLOCKWISE until
lightly-snug.
Hydraulic hose or fitting
leak.
Contact an authorized
Ricon dealer for repair.
END OF TABLE